Inverter Toshiba Tosvert VF-AS1 3-phase 400V 0.75kW-500kW

Inverter-Toshiba-Tosvert-VF-AS1-3-phase-400V-0.75kW-500kW

High performance Inverter Tosvert

VF-AS1 3-phase 400V Models

  • VFAS1-4007PL = 0.75kW
  • VFAS1-4015PL = 1.5kW
  • VFAS1-4022PL = 2.2kW
  • VFAS1-4037PL = 3.7kW
  • VFAS1-4055PL = 5.5kW
  • VFAS1-4075PL = 7.5kW
  • VFAS1-4110PL = 11kW
  • VFAS1-4150PL = 15kW
  • VFAS1-4185PL = 18.5kW
  • VFAS1-4220PL = 22kW
  • VFAS1-4300PL = 30kW
  • VFAS1-4370PL = 37kW
  • VFAS1-4450PL = 45kW
  • VFAS1-4550PL = 55kW
  • VFAS1-4750PL = 75kW
  • VFAS1-4900PC  = 90kW
  • VFAS1-4110KPC = 110kW
  • VFAS1-4132KPC = 132kW
  • VFAS1-4160KPC = 160kW
  • VFAS1-4200KPC = 200kW
  • VFAS1-4220KPC = 220kW
  • VFAS1-4280KPC = 280kW
  • VFAS1-4355KPC = 355kW
  • VFAS1-4400KPC = 400kW
  • VFAS1-4500KPC = 500kW

Standard Specifications

Item Specification
Applicable motor (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Rating Type VFAS1-
Form 4007PL 4015PL 4022PL 4037PL 4055PL 4075PL 4110PL 4150PL 4185PL 4220PL 4300PL 4370PL 4450PL 4550PL 4750PL
Output Capacity (kVA) Note 1) 1.8 3.1 4.4 8.0 11 13 21 25 31 37 50 60 72 88 122
Output Current (A) Note 2) 2.3
(2.3)
4.1
(4.0)
5.8
(4.6)
10.5
(8.6)
14.3
(13)
17.6
(17)
27.7
(25)
33
(32)
41
(37)
48
(38)
66
(53)
79
(60)
94
(75)
116
(93)
160
(120)
Output Voltage 3-phase, 380 to 480 V (The maximum output voltage is the same as the input voltage.)
Overload current rating 150% – 1 minute
Electric braking Dynamic Braking Circuit Built-in
Dynamic Breaking Resistor Compatible with external options
Power supply Voltage-frequency 3-phase, 380 to 480 V . 50/60 Hz
Allowable fluctuation Voltage +10% – 15% Note 3) Frequency +/-5%
Protective method IP20 enclosed type (JEM1030) IP00 enclosed type (JEM1030) Note 4)
Cooling method Forced air-cooled
Cooling fan noise (dBA) 43 43 43 55 56 56 58 60 60 60 64 64 64 64 64
Color RAL7016
Built-in Filter EMI noise filter Note 5)
DC Reactor External option Built-in

Note 1) Rated output current when the PWM carrier frequency (parameter ) is 4kHz or less. The values between parentheses refer to rated output currents when set to 12kHz.
Note 2) +/-10% when the inverter is used continuously (load of 100%)
Note 3) Inverters, 18.5kW or greater, do not have wiring port covers. They have large openings, but there is no space to bend the external cables inside the unit. If they are fitted external to the cabinet, please use an optional wiring port cover.
Note 4) Complies with the Europian EMC Directive IEC/EN61800-3, 1st environment, category C2 or IEC/EN61800-3, 2nd environment, category C3
Note 5) Not complies with the European EMC Directive Core and capacities with external filter (optional) : Complies with the Europien EMC Directive.

 

Standard specifications (400 V class -90 to 500 kW model)

Item Specification
Applicable motor (kW) 90 110 132 160 200 220 280 355 400 500
Rating Type VFAS1-
Form 4900PC 4110KPC 4132KPC 4160KPC 4200KPC 4220KPC 4280KPC 4355KPC 4400KPC 4500KPC
Output Capacity (kVA) Note 1) 136 164 197 239 295 325 419 511 578 717
Output Current (A) Note 2) 179 215 259 314 387 427 550 671 759 941
Output Voltage 3-phase, 380 to 480 V (The maximum output voltage is the same as the input voltage.)
Overload Current Rating 150% – 1 minute
Electric braking Dynamic Braking Circuit Built-in Compatible with external options
Dynamic Breaking Resistor Compatible with external options
Power supply Voltage/frequency Note 6) 3-phase, 380 to 440 V . 50 Hz
3-phase, 380 to 480 V . 60 Hz
Allowable Fluctuation Voltage +10% . 15% Note 3) Frequency +/-5%
Protective method IP00 open type (JEM1030) Note 4)
Cooling method Forced air cooling
Cooling fan noise (dBA) 61 72 73 73 76 76 76 76 76 78
Color RAL7016
Built-in Filter EMI noise filter Note 7)
DC Reactor Attached DC reactor Note 5)